MetecnoTherm R1.25 is a 30 mm rigid polyisocyanurate board with a flexible foil facing on both sides, made by Metecno in Australia. Board size 2400 x 1200 mm, 2.88 m² per board. Priced per board.

What 30 mm buys you

Declared R1.25 at 23 degrees, or R1.35 at 15 degrees. In a wall the certified total rises to R1.51 at 15 degrees, and in a ceiling to R1.50. This is a common under slab and soffit thickness where the depth available is tight.

Against a batt

Thermal conductivity is 0.024 W/m·K, roughly half that of glasswool. To reach R1.25 with a glasswool batt you would be looking at about 65 mm of depth instead of 30 mm. That is the whole reason a rigid board gets specified: the cavity depth is fixed and the batt cannot get there.

Fire, stated plainly

Group Number 2 with the embossed foil face, tested to AS ISO 9705 and assessed to AS 5637.1:2015. The CodeMark certificate also states it has not been tested to AS 1530.1 and cannot be treated as non-combustible. If the job needs non-combustible material, this is not the board for it. As an internal wall or ceiling lining the Group Number has to satisfy Table S7C4 of Specification 7, NCC Volume One.

Ordering

Sold per board. A full pallet is 37 boards, 106.56 m². Metecno make the range in 5 mm increments and in white, black, plasterboard and fibre cement faced versions, all to order. Ask us for anything not listed, or for pallet freight on a large order.

Other thicknesses

See the full rigid board range for the other nine MetecnoTherm thicknesses from 25 mm to 100 mm.

Metecno · Polyisocyanurate (PIR) rigid foam core between flexible embossed foil facings · Wall, ceiling and underfloor insulation board application

Sizes stocked

Board sizeThicknessArea per boardBoards per palletProduct code
2400 x 1200 mm30 mm2.88 m²37PIR-MTG2-30

Thermal

Declared R-value at 23 °C R1.25
Declared R-value at 15 °C R1.35
Declared thermal conductivity at 23 °C 0.024 W/m·K
Wall total R-value R1.58 at 6 °C, R1.51 at 15 °C, R1.40 at 30 °C
Ceiling total R-value R1.57 at 6 °C, R1.50 at 15 °C, R1.44 at 30 °C

Total R-values are the certified figures for the board within a wall or ceiling element and vary with mean temperature.

Fire

Group Number, embossed foil face 2 (AS ISO 9705:2003, assessed to AS 5637.1:2015)
SMOGRARC 137.4 m²s-2 x 1000
Combustibility Not tested to AS 1530.1-1994 and cannot be considered non-combustible
Internal linings Use as an internal wall or ceiling lining must comply with the Group Number in Table S7C4, Specification 7, NCC Volume One 2022

Group Number source: Ignis Labs report IGNL-8205-99-01R I01 R02, dated 27 August 2024.

Construction

Core Polyisocyanurate (PIR)
Board size 2400 x 1200 mm
Thickness 30 mm
Area per board 2.88 m²
Facings Embossed foil, paper or coated glass fibre
Manufacturer range 25 to 100 mm in 5 mm increments

Compliance

Certificate CodeMark CM40415-I01-R01, issued 3 March 2026, expires 29 August 2027
Certification body CMI Certification Pty Ltd, JASANZ accreditation Z4450210AK
Certificate holder Metecno Pty Ltd trading as Metecno, Bondor
BCA 2022 Amendment 2 Volume One C2D11 fire hazard properties, Volume Two H6D2 energy efficiency, J4D3 thermal construction
Building classes 1, 2, 3, 4, 5, 6, 7, 8, 9 and 10

The certificate is only valid reproduced in full and carries limitations and conditions. Read it before relying on it for a submission.

Fitting notes

Installation must follow the MetecnoTherm Design and Install Guide version 5, which the CodeMark certificate names as a condition of the certification. Structural support members are designed separately by the building designer or engineer. Cut the boards cleanly and butt the joints tight, because a rigid board loses more to a gap than a batt does. Where the board is an internal lining, check the Group Number requirement for that room before specifying.

Figures are taken from the Metecno CodeMark Certificate of Conformity CM40415-I01-R01, issued 3 March 2026, which carries the certified product technical data in Appendix A. Product code, pallet quantity and pricing are from the RM Industries price list of May 2026. The certificate is linked above.

Common questions

What R-value do I actually get with 30 mm?

R1.25 declared at 23 degrees for the board on its own. Inside a wall element the certified total is R1.51 at 15 degrees, and in a ceiling R1.50, because the adjacent air spaces add to it.

Is MetecnoTherm non-combustible?

No, and the certificate says so directly. It has not been tested to AS 1530.1 and cannot be considered a non-combustible product. Its Group Number is 2 with the embossed foil face.

How thick would a batt need to be to match 30 mm of this?

Roughly about 65 mm. PIR is about 0.024 W/m·K against roughly 0.044 for glasswool, so it does the same job in about half the depth.

Am I buying one board or a pack?

One board, 2400 x 1200 mm, 2.88 m². A full pallet is 37 boards or 106.56 m² if you need that quantity.

Can I use it as an internal lining?

Only where Group Number 2 satisfies Table S7C4 of Specification 7 in NCC Volume One 2022 for that use. Metecno also make plasterboard and fibre cement faced versions that achieve Group 1.

Can I get a different facing or thickness?

Metecno make the range in 5 mm increments, and in white or black facing at a 25 percent surcharge on a four week lead time. Plasterboard and fibre cement faced versions are also available. Contact us for a quote.

How many boards do I need?

Divide the area by 2.88 m² and round up, then allow for cuts at openings and edges. A rigid board wastes more at a complicated perimeter than a batt does.

Cannot see your question? Ask our team and we will get you an answer.

Answers use the Metecno CodeMark Certificate of Conformity CM40415-I01-R01 and the RM Industries price list of May 2026.