AIR-CELL Insulwhite

AIR-CELL Insulwhite

$452.53
Sale price  $452.53 Regular price  $476.35
Skip to product information
AIR-CELL Insulwhite
1/3

AIR-CELL Insulwhite

$452.53
Sale price  $452.53 Regular price  $476.35
GST inclusive

Dispatch: Most orders are processed the same day. Metro delivery: Usually 1–3 business days. We do our best to get most items out on the next business day.

Australia-wide freight · Local pickup from Epping, VIC by arrangement. Ordering from the outback? Get in touch about deliveries to remote locations · Shipping details

AIR-CELL Insulwhite is an Australian made closed cell foam blanket with a reflective foil face on one side and a white face on the other, made for exposed roof and attic linings. CodeMark certified for NCC compliance.

The white face is why it exists

In a space where the underside of the roof is visible, a bright foil finish looks unfinished and glares. The white face gives a clean surface that also lifts the light level, while the reflective face works upward against the air gap under the sheeting. Kingspan quotes 97% reflectance on the reflective face with an emittance of 0.03.

System figures

Material R-value is R0.15, which is the reflective product story again: the number that matters is what the system reaches. In a residential metal roof Kingspan quotes RT 1.9 for heat flowing in and RT 1.0 for heat flowing out.

Barrier performance

Class 2 vapour barrier and a water barrier to AS/NZS 4201.4, with low surface water absorbency. Flammability index 5 or lower. Burst strength 1.0 kN and a maximum unsupported span of 2.4 m.

Roll

1350 mm x 22.25 m covering 30 m² at 5.5 mm thick, weighing 7.65 kg. Fibre-free, non-allergenic, non-irritant, and rodent and insect resistant.

Full figures are in the table below.

Kingspan Insulation · Cross-linked closed cell foam, foil one side and white the other · Exposed roof and attic lining application

Sizes stocked

Roll sizeAreaNominal thicknessRoll weightRoll diameter
1350 mm x 22.25 m30 m²5.5 mm7.65 kg450 mm

Thermal

Material R-value R0.15 m²K/W at 23 °C (ASTM C518-2017)
Reflectance, reflective face 97%
Emittance 0.03 reflective face, white face non-reflective, category RN

Total system R-value

Residential metal roof, heat flow in RT 1.9
Residential metal roof, heat flow out RT 1.0

Total R-value for the building element as the NCC energy provisions require it, calculated to AS/NZS 4859.2:2018.

Moisture and air control

Vapour control Class 2 vapour barrier, under 0.020 µg/N·s (ASTM E96 Part B)
Water control Water barrier (AS/NZS 4201.4)
Surface water absorbency Low, under 100 g/m²
Moisture shrinkage Under 0.5%
Corrosion resistance Pass (AS/NZS 4859.1 Appendix E)

Physical and fire

Flammability index 5 or lower, Low (AS 1530.2)
Burst strength 1.0 kN (AS 3706.4 CBR)
Maximum span 2.4 m without support
Dry and wet delamination Pass (AS/NZS 4201.1 and 4201.2)
Other Fibre-free, non-allergenic, non-irritant, water resistant, rodent and insect resistant

Compliance

Certification CodeMark certified for NCC compliance
Thermal rating Manufactured, tested and packaged to AS/NZS 4859.1:2018
Origin Made in Australia

Fitting notes

Made for jobs where the underside stays in view, such as an attic conversion or a raked ceiling, so the white face goes inwards and becomes the finish. Roll it out under the rafters and fix with 25 mm button head timber screws with a white painted head and at least a 12 mm head diameter. Use four screws across the width at each rafter, one 25 mm in from each edge and the other two around 430 mm apart. Butt join and tape with white 72 mm tape for the neatest result, or lap 50 mm and tape. Keep 100 mm clear of flues and light fittings.

Figures are taken from the Kingspan Insulation product data sheet for AIR-CELL Insulwhite, Australian edition. The full manufacturer document is linked above. Kingspan can change specifications without notice, so check the current sheet before specifying on a job.

Common questions

What sizes are stocked and how much does each one cover?

It is stocked in one option, 1350 mm x 22.25 m. The table above lists the coverage or quantity you get.

What thermal performance does it have?

Material R-value: R0.15 m²K/W at 23 °C (ASTM C518-2017). Emittance: 0.03 reflective face, white face non-reflective, category RN. Thermal rating: Manufactured, tested and packaged to AS/NZS 4859.1:2018.

How does it handle moisture?

Vapour control: Class 2 vapour barrier, under 0.020 µg/N·s (ASTM E96 Part B). Water control: Water barrier (AS/NZS 4201.4). Surface water absorbency: Low, under 100 g/m². Moisture shrinkage: Under 0.5%. Dry and wet delamination: Pass (AS/NZS 4201.1 and 4201.2).

Does it meet Australian standards?

Certification: CodeMark certified for NCC compliance.

How is it installed?

Made for jobs where the underside stays in view, such as an attic conversion or a raked ceiling, so the white face goes inwards and becomes the finish. Roll it out under the rafters and fix with 25 mm button head timber screws with a white painted head and at least a 12 mm head diameter. Use four screws across the width at each rafter, one 25 mm in from each edge and the other two around 430 mm apart. Butt join and tape with white 72 mm tape for the neatest result, or lap 50 mm and tape. Keep 100 mm clear of flues and light fittings.

Cannot see your question? Ask our team and we will get you an answer.

Figures are taken from the Kingspan Insulation product data sheet for AIR-CELL Insulwhite, Australian edition. The full manufacturer document is linked above. Kingspan can change specifications without notice, so check the current sheet before specifying on a job.

You may also like