R3.5 Pink Ceiling Batts
Dispatch: Most orders are processed the same day. Metro delivery: Usually 1–3 business days. We do our best to get most items out on the next business day.
Australia-wide freight · Local pickup from Epping, VIC by arrangement. Ordering from the outback? Get in touch about deliveries to remote locations · Shipping details
R3.5 Pink Ceiling Batts are 175 mm FBS-1 bio-soluble glasswool batts from Fletcher, Australian made using up to 80% recycled content. R3.5 is one of the most commonly specified ceiling values in Australian housing.
Fire and bushfire
Non-combustible to AS/NZS 1530.1, with ignitability, spread of flame and heat evolved indices all at 0 and smoke developed at 0 to 1. Rated for bushfire areas from BAL Low through to Flame Zone under AS 3959, and it meets NCC 2022 clause C2D10(1) for non-combustibility. If the site has a BAL rating, this is a batt that does not restrict you.
It is also an acoustic batt
NRC is 1.10 with an airflow resistance of 2700 Rayls/m, which is genuine absorption rather than a token figure. In a ceiling that means less noise carrying between the roof space and the rooms below, and less reverberation in large open rooms.
Sizes
Two widths at 1160 mm long. The 430 mm comes 16 to a pack covering 7.98 m², the 580 mm comes 10 to a pack covering 6.73 m². Note the wider batt covers less per pack, not more, so estimate on the square metre figure.
On site
Cuts with a knife and friction fits between the joists, so it holds without fixings. Let the batts recover to full loft before installing and do not compress them into the space. Keep them dry, and keep the clearances downlights and flues require.
Full thermal, fire, acoustic and compliance figures are in the table below.
Technical data
Fletcher technical data sheet (PDF)Sizes stocked
| Size (L x W x thickness) | Batts per pack | Pack size | Product code (old / new) |
|---|---|---|---|
| 1160 x 430 x 175 mm | 16 | 7.98 m² | 901354 / 4006102 |
| 1160 x 580 x 175 mm | 10 | 6.73 m² | 901355 / 4006103 |
Thermal
| Material R-value | R3.5 m²K/W |
|---|---|
| Nominal thickness | 175 mm |
| Maximum service temperature | 340 °C (ASTM C411/C447) |
Fire
| Combustibility | Non-combustible (AS/NZS 1530.1) |
|---|---|
| Ignitability index | 0 |
| Spread of flame index | 0 |
| Heat evolved index | 0 |
| Smoke developed index | 0 to 1 |
| Bushfire areas | BAL Low through to Flame Zone (AS 3959) |
Early fire hazard indices tested to AS/NZS 1530.3.
Acoustic
| NRC | 1.10 |
|---|---|
| αw | 1.0 |
| Sound absorption at 500 Hz | 1.0 |
| Airflow resistance | 2700 Rayls/m (ASTM C522) |
Absorption coefficients measured to AS ISO 354 at 175 mm.
Material and handling
| Composition | FBS-1 bio-soluble glasswool |
|---|---|
| Moisture absorption | Under 0.2% by volume |
| Fungi resistance | Pass, no growth (ASTM C1338-14) |
| Ozone depleting substances | None used in manufacture |
| Recycled content | Australian made using up to 80% recycled content |
Compliance
| Thermal rating | Complies with AS/NZS 4859.1 |
|---|---|
| NCC 2022 | AS/NZS 4859.1 per Volume 1 J4D3(1) and ABCB Housing Provisions 3.12.2(1) |
| NCC 2022 non-combustibility | Non-combustible per AS/NZS 1530.1, meets clause C2D10(1) |
Compliance applies when the product is correctly specified and installed.
Fitting notes
Cuts with a knife and friction fits between joists, so it holds without fixings. Keep batts at full loft and let them recover before installing. Do not compress them into the space, because a squashed batt delivers less than its rated R-value. Keep the product dry at all times, before, during and after installation.
Figures are taken from the Fletcher Insulation technical data sheet for Pink Batts Ceiling, RTDS9 Revision 7, issued 17 February 2025. The full manufacturer document is linked above. Fletcher can change specifications without notice, so check the current sheet before specifying on a job.
Common questions
What sizes are stocked and how much does each one cover?
2 options are stocked, running from 1160 x 430 x 175 mm to 1160 x 580 x 175 mm. The table above lists each one with the coverage or quantity you get.
What thermal performance does it have?
Material R-value: R3.5 m²K/W. Maximum service temperature: 340 °C (ASTM C411/C447). Thermal rating: Complies with AS/NZS 4859.1.
How does it perform in a fire?
Combustibility: Non-combustible (AS/NZS 1530.1). Ignitability index: 0. Spread of flame index: 0. Heat evolved index: 0. Smoke developed index: 0 to 1. NCC 2022 non-combustibility: Non-combustible per AS/NZS 1530.1, meets clause C2D10(1).
Can it be used in a bushfire area?
Bushfire areas: BAL Low through to Flame Zone (AS 3959).
What acoustic performance can I expect?
Sound absorption at 500 Hz: 1.0.
How does it handle moisture?
Moisture absorption: Under 0.2% by volume. Fungi resistance: Pass, no growth (ASTM C1338-14).
Does it meet Australian standards?
NCC 2022: AS/NZS 4859.1 per Volume 1 J4D3(1) and ABCB Housing Provisions 3.12.2(1).
What is it made of?
Composition: FBS-1 bio-soluble glasswool.
How is it installed?
Cuts with a knife and friction fits between joists, so it holds without fixings. Keep batts at full loft and let them recover before installing. Do not compress them into the space, because a squashed batt delivers less than its rated R-value. Keep the product dry at all times, before, during and after installation.
Cannot see your question? Ask our team and we will get you an answer.
Figures are taken from the Fletcher Insulation technical data sheet for Pink Batts Ceiling, RTDS9 Revision 7, issued 17 February 2025. The full manufacturer document is linked above. Fletcher can change specifications without notice, so check the current sheet before specifying on a job.