ThermalBreak 7 is a foil faced XPE foam sarking made for one specific job: the thermal break the NCC asks for where cladding fixes straight onto steel framing. Material R-value is 0.21 m²K/W, and 0.20 once it is compressed.

Why the compressed figure is the one that counts

A thermal break gets squashed the moment the cladding screws go through it. A product that only holds its rating uncompressed is not doing the job on site. This one still holds R0.20 compressed, which is exactly what the code asks for at those junctions. Thermal breaks explained covers where the requirement applies and why such a small number matters at all.

What it does beyond the thermal break

It is also a Class 2 vapour barrier, a water barrier to AS/NZS 4201.4 and an air barrier, classified Extra Heavy duty to AS/NZS 4200.1:2017. Fire is Group 1 to AS 5637.1 with a Low flammability classification, and it is suitable for all Bushfire Attack Levels. Get independent advice before locking a sarking into a BAL design.

System values

An independent engineer calculated total system R-values to AS/NZS 4859.2:2018 for typical mainland capital city conditions under NCC 2019: RT 0.92 in winter and 2.02 in summer for a warehouse roof with no ceiling, and RT 2.07 winter and 2.03 summer in a double brick wall. Those figures were calculated against NCC 2019 and may not carry across to other editions of the code, so check before relying on them for a current submission.

Roll and fitting

One roll size: 1350 mm by 22.25 m plus a 150 mm flap, covering 30 m², over a 7.8 mm foam core. Fix it over the steel frame before the cladding goes on so it sits between frame and sheet and breaks the conduction path, and lap the runs onto the flap rather than butting them. Do not stretch it drum tight over the studs, because the compressed R0.20 figure assumes there is still foam there to compress. The foil conducts electricity, so keep it clear of wiring.

Full figures are in the table below.

Ametalin · Foil faced XPE foam · Thermal break for steel and timber framing application

Sizes stocked

CodeRoll sizeArea per rollFoam core
TB7-301350 mm x 22.25 m plus 150 mm flap30 m²7.8 mm

Thermal

Material R-value 0.21 m²K/W (ASTM C518)
Compressed material R-value 0.20 m²K/W
Thermal conductivity 0.0376 W/m·K
Thermal conductance 4.7 W/m²K
Emittance 0.05 anti-glare side, 0.03 foil side, IR reflective, category RR

The compressed figure is the one that counts. It still holds R0.20 once it is squashed under the cladding fixings, which is exactly what the NCC asks for as a thermal break in steel framed construction.

Total system R-value

Warehouse roof, no ceiling, winter RT 0.92
Warehouse roof, no ceiling, summer RT 2.02
Double brick wall, winter RT 2.07
Double brick wall, summer RT 2.03

Calculated by an independent engineer to AS/NZS 4859.2:2018 for typical mainland Australian capital city conditions under NCC 2019. Values may not carry across to other editions of the code.

Moisture and air control

Vapour control Class 2 vapour barrier (ASTM E96)
Vapour permeance 0.0113 µg/N·s
Water control Water barrier (AS/NZS 4201.4)
Air control Air barrier

Fire

Group number Group 1 (AS 5637.1)
Flammability classification Low (AS 1530.2)
Bushfire areas Suitable for all Bushfire Attack Levels

Get independent advice on sarking selection before locking it into a BAL design.

Classification and strength

Duty Extra Heavy (AS/NZS 4200.1:2017)
Electrical conductivity Conductive
Tensile strength, machine direction 14.6 kN/m (minimum 9.5)
Tensile strength, lateral direction 13.6 kN/m (minimum 6.0)
Edge tear, machine direction 384 N (minimum 65)
Edge tear, lateral direction 293 N (minimum 65)
Dry and wet delamination Pass (AS/NZS 4201.1 and 4201.2)

Build-up

Core 7.8 mm chemically cross-linked closed cell XPE foam
Face 1 Aluminium foil with anti-glare coating, emissivity 0.03
Face 2 Polymer weave, emissivity 0.05

Fitting notes

Fixed over the steel frame before the cladding goes on, so it sits between the frame and the sheet and breaks the conduction path. Lap the runs onto the 150 mm flap rather than butting them. It also works on timber frame and on commercial steel frame. Do not stretch it drum tight over the studs, because the compressed R0.20 figure assumes the foam is still there to compress. The foil conducts electricity, so keep it clear of wiring.

Figures are taken from the Ametalin technical data sheet for ThermalBreak, document APM-45758-2, product code TB7. The full manufacturer document is linked above. Ametalin can change specifications without notice, so check the current sheet before specifying on a job.

Common questions

What sizes are stocked and how much does each one cover?

It is stocked in one option, TB7-30. The table above lists the coverage or quantity you get.

What thermal performance does it have?

Material R-value: 0.21 m²K/W (ASTM C518). Compressed material R-value: 0.20 m²K/W. Thermal conductivity: 0.0376 W/m·K. Thermal conductance: 4.7 W/m²K. Emittance: 0.05 anti-glare side, 0.03 foil side, IR reflective, category RR. Electrical conductivity: Conductive.

Can it be used in a bushfire area?

Bushfire areas: Suitable for all Bushfire Attack Levels.

How does it handle moisture?

Vapour control: Class 2 vapour barrier (ASTM E96). Vapour permeance: 0.0113 µg/N·s. Water control: Water barrier (AS/NZS 4201.4). Dry and wet delamination: Pass (AS/NZS 4201.1 and 4201.2).

Does it meet Australian standards?

Flammability classification: Low (AS 1530.2).

How is it installed?

Fixed over the steel frame before the cladding goes on, so it sits between the frame and the sheet and breaks the conduction path. Lap the runs onto the 150 mm flap rather than butting them. It also works on timber frame and on commercial steel frame. Do not stretch it drum tight over the studs, because the compressed R0.20 figure assumes the foam is still there to compress. The foil conducts electricity, so keep it clear of wiring.

Cannot see your question? Ask our team and we will get you an answer.

Figures are taken from the Ametalin technical data sheet for ThermalBreak, document APM-45758-2, product code TB7. The full manufacturer document is linked above. Ametalin can change specifications without notice, so check the current sheet before specifying on a job.