Rhino Cell 310 AG roll partly unrolled, anti-glare face up, with the silver reflective face on the outside of the roll

Rhino Cell 310 AG Thermal Break Bubble Foil Insulation

1350 mm x 22.25 m, 150 mm flap (30 m²)
$279.00
Sale price  $279.00 Regular price 
Skip to product information
Rhino Cell 310 AG roll partly unrolled, anti-glare face up, with the silver reflective face on the outside of the roll

Rhino Cell 310 AG Thermal Break Bubble Foil Insulation

$279.00
Sale price  $279.00 Regular price 
GST inclusive

Opening Offer: 5% off orders over $1,000, 7% over $2,500, 10% over $4,000. Ends 30 November. Offer details

Size1350 mm x 22.25 m, 150 mm flap (30 m²)

Dispatch: Most orders are processed the same day. Metro delivery: Usually 1–3 business days. We do our best to get most items out on the next business day.

Delivery to VIC and NSW: $55 in metro Melbourne and metro Sydney, $99 in the outer ring around both cities, $149 anywhere else in the two states · Local pickup from Epping, VIC by arrangement · Shipping details

Rhino Cell 310 AG is Thor Building Products' 11 mm reflective bubble insulation, rated R0.20 as a material. Thor describe it as a 3 in 1 insulation, vapour barrier and radiant heat barrier for roof, wall and floor systems.

Thermal break rating

Thor state it achieves a thermal break of R0.2, against R0.10 for the 4 mm Rhino Cell 104 AG. The data sheet cites no test report or certificate, so ask your certifier first. Our R0.2 thermal break article explains where the NCC requires one.

Foil needs an air space

Thor's total R-values assume a reflective air space beside the foil. A flat metal roof with a suspended ceiling and at least 300 mm of air space reaches RT 2.77 in summer and RT 1.23 in winter. Dust on upward facing foil lowers them. It is a Class 2 vapour barrier. Check the condensation provisions for your climate zone.

Bushfire ratings differ

Flammability index is Low (5 or less) to AS 1530.2. Thor rate it BAL LOW to BAL 40 in roofs and BAL LOW to BAL FZ in walls. A BAL FZ roof needs another product.

On site

Each roll is 1350 mm wide plus a 150 mm flap, 22.25 m long, covers 30 m² and weighs about 12.5 kg. Thor say the flap removes the need for overlap, saving up to 10%. Keep at least 50 mm clear of light fittings and hot flues, and use plastic fixings near wiring because the foil conducts electricity. Install to AS 4200.2. Full figures are in the table below.

Rhino · Triple layer polyethylene bubble core with two layers of high density polyethylene weave, faced with anti-glare coated aluminium foil on one side and reflective aluminium foil on the other · Insulation, vapour barrier and radiant heat barrier for roof, wall and floor systems, with an R0.2 thermal break rating from Thor application

Sizes stocked

Roll sizeFlapCoverageThicknessRoll weight (approx.)Product code
1350 mm x 22.25 m150 mm30 m²11 mm12.5 kgRC-310AG

Thermal

Material R-value R0.20 m²K/W
Thermal break R0.2, as stated by Thor
Emissivity Reflective silver face 0.03, anti-glare face 0.05
Reflectivity Anti-glare face 95%, reflective face 97%

These are material figures; what the roof or wall achieves depends on the air space beside the foil.

Thermal, Thor total R-values (winter heat flow out / summer heat flow in)

Flat metal roof, suspended ceiling, 300 mm min. reflective air space 1.23 / 2.77
Pitched metal roof 22 degrees, flat ceiling, unventilated attic space 1.40 / 2.10
Pitched metal roof 22 degrees, flat ceiling, ventilated attic space 1.20 / 2.40
Metal clad wall, 100 mm min. reflective air space 1.60 / 1.50
Basis AS/NZS 4859.1

Thor note that dust on upward facing surfaces and in ventilated cavities reduces these figures.

Fire

Flammability index Low (≤5), AS 1530.2
Early fire hazard indices 0/0/0/1
Bushfire, roof systems BAL LOW to BAL 40
Bushfire, wall systems BAL LOW to BAL FZ

The roof rating stops at BAL 40, so a BAL FZ roof needs a different product.

Vapour, water and membrane tests

Vapour classification (VCM) Class 2, Vapour Barrier
Water control classification Water Barrier
Surface corrosion Pass
Resistance to dry delamination Pass
Resistance to wet delamination Pass
Electrical conductivity Conductive

Check the condensation provisions for the climate zone before using a vapour barrier under a metal roof.

Strength, material and handling

Duty rating, tensile strength Extra Heavy Duty
Duty rating, edge tear resistance Extra Heavy Duty
Core Triple layer polyethylene bubble, contains up to 20% recycled material
Reinforcement Two layers of high density polyethylene weave
Facings Aluminium foil with anti-glare coating on one side, aluminium foil on the other
Composition (safety data sheet) Polyethylene over 95%, aluminium foil under 5%
Fibres Fibre-free, non-allergenic, formaldehyde free
Pests Rodent and insect resistant (Thor product page)
Origin Australian made

Compliance

Product standards AS 4859.1 and AS 4200.1
Installation standard AS 4200.2

Fitting notes

Install to AS 4200.2. Thor say the 150 mm flap removes the need for an overlap, saving up to 10%. Before fitting, check that all electrical cabling, fittings and wiring are in a safe condition and that the foil cannot touch live wiring or downlights. Keep at least 50 mm clear of light fittings (check the safe distance with the lighting supplier) and 50 mm clear around hot flues. Use plastic fixings where electrical components are close to the work, and no metal fixings near electrical wiring. Thor's total R-values assume a reflective air space beside the foil, at least 300 mm under a flat metal roof with a suspended ceiling and at least 100 mm in a metal clad wall. No protective equipment is required, but Thor recommend UV protective sunglasses when installing outside.

Figures are taken from the Thor Building Products data sheet for Rhino Cell 310 AG + Flap, product code RC-310 AG, July 2022. The manufacturer document is linked above. The composition comes from Thor's safety data sheet for Rhino Cell (November 2019) and the rodent and insect note from Thor's RC-310AG product page. Thor can change specifications without notice, so check the current sheet before specifying on a job.

Common questions

Is Rhino Cell 310 AG a thermal break?

Thor rate the material at R0.20 and state that it achieves a thermal break of R0.2. The data sheet gives no test report or certificate for that figure, so confirm with your certifier before relying on it as an NCC thermal break.

What R-value will my roof actually get?

The material alone is R0.20. Thor's total for a 22 degree pitched metal roof over a flat ceiling and an unventilated attic is RT 1.40 in winter (heat flow out) and RT 2.10 in summer (heat flow in). Dust on upward facing foil and in ventilated cavities lowers these figures.

How much does one roll cover?

Each roll is 1350 mm wide plus a 150 mm flap and 22.25 m long, and Thor rate it at 30 m². Thor say the flap removes the need for an overlap, saving up to 10%.

Can it be used in a bushfire prone area?

Thor rate it from BAL LOW to BAL 40 in roof systems and from BAL LOW to BAL FZ in wall systems. It is not rated for a BAL FZ roof.

Is it a breathable membrane?

No. Thor classify it as a Class 2 vapour barrier and a water barrier. Check the condensation provisions for your climate zone before putting a vapour barrier under a metal roof.

Is it safe near wiring and downlights?

The foil is electrically conductive. Thor ask for at least 50 mm clearance from light fittings and hot flues, plastic fixings where electrical components are close, and no metal fixings near electrical wiring.

What is the difference between Rhino Cell 310 AG and Rhino Cell 104 AG?

The 310 is 11 mm thick with a material R-value of R0.20. The 104 is 4 mm nominal and R0.10. Both come as 30 m² rolls with a 150 mm flap.

Cannot see your question? Ask our team and we will get you an answer.

Answers use Thor Building Products' data sheets for Rhino Cell 310 AG + Flap (July 2022) and Rhino Cell 104 AG (August 2021).

You may also like